LG · Laundry · DLEX4000B · Owner's Manual
Final installation checks and test run
Final installation checks and test run from LG DLEX4000B Owner's Manual. Read the extracted page 28-30, related manual answers, and source citation.
LG · Laundry · DLEX4000B · Owner's Manual
Final installation checks and test run from LG DLEX4000B Owner's Manual. Read the extracted page 28-30, related manual answers, and source citation.
Source integrity
This extracted section stays tied to manual review status, source text, citation, original source URL, text export, manual catalog, related answers, and nearby source sections.
Section pages inherit the manual review and index status before they are treated as public source pages.
The manual section keeps extracted body text available on-page for inspection and citation.
The section carries its own citation string so the source page or page range remains visible.
The parent manual keeps its manufacturer, support, or source-host URL attached.
The parent manual exposes a public plain-text export for source verification and machine-readable use.
The parent manual exposes a machine-readable catalog with sections, questions, and coverage metadata.
Reviewed answers that cite this section link users from concise answers back to the exact source text.
Adjacent and same-topic manual sections keep the source page connected to the rest of the manual.
This source section links the manual text to the model hub, reviewed answers, troubleshooting, codes, parts, and nearby source pages.
This page preserves the extracted manual text, source citation, and neighboring source sections.
Use the model hub to compare this section with answers, guides, codes, and part references.
Reviewed answers cite this section directly so users can jump from a short answer back to the exact source text.
Troubleshooting pages use source manual context to keep checks connected to the product and manual trail.
Part references keep filters, racks, panels, pumps, and service items connected to the same product context.
Move through adjacent source sections or same-topic sections without returning to the full table of contents.
Before using the dryer normally, make three final checks: levelness, airflow, and the installation test.
1) Check that the dryer is level Once the dryer is in its final location, recheck it to make sure it is level: - front to back - side to side - all four leveling feet should be in firm contact with the floor
2) Check airflow Good dryer performance depends on proper airflow. The manual says airflow can be checked by measuring static pressure in the exhaust duct with a manometer.
If the ductwork is crushed or restricted, or if there are blockages or lint buildup, airflow can be poor. The manual also notes that long exhaust runs, multiple elbows, bends, excess transition duct, or crushed transition duct can restrict airflow.
3) Run the installation test This test is meant to confirm that the exhaust system is adequate for proper operation. The appliance should be cool before you start. If it was warmed up during installation, run the Air Dry cycle for a few minutes first to lower the interior temperature.
Flow SenseTM is a sensing system that detects blockages and restrictions in the dryer ductwork. Keeping the ductwork clean and free of restrictions helps clothes dry faster and reduces energy use.
Before you start - Remove the drying rack and literature - Close the door - Do not load anything in the drum for this test, because that can affect the accuracy of the results
How to activate the installation test 1. Press and hold the Signal and Temp. buttons, then press the Power button. - On models with a glass touch control panel, press Power first, then immediately press and hold Signal and Temp. - If the activation is successful, code 1Ns will display. 2. Press Start/Pause. - The test lasts a few minutes. - Heat will turn on and the temperatures in the drum will be measured. 3. Check the display and Flow SenseTM LED when the test ends.
How to read the result - If the Flow SenseTM LED does not turn on when the cycle ends, the exhaust system is adequate. - If the Flow SenseTM LED turns on, the exhaust system is severely restricted and should be checked immediately, because performance will be poor. - Other problems may also appear as error codes. - At the end of the test cycle, ENd will display and the appliance will shut off automatically after a short delay.
If the test shows a problem If the Flow SenseTM LED turns on, check the exhaust system for restrictions and damage, then repair or replace it as needed.
The manual also says: - Do not interrupt the test cycle, or the results may be inaccurate - Even if the LED does not light during the test, some restrictions may still be present - Refer to the Venting the Dryer section for complete exhaust system and venting requirements
Error codes mentioned in this section - Ps, PF, or NP: electric dryer power cord is not connected correctly, or house power supply is incorrect. Reset the circuit breaker or replace the fuse. Do not increase the fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician. - GAs: gas supply or service is turned off, gas model only. Confirm that the house gas shutoff and the dryer gas shutoff are both fully open. - tE1 or tEz: temperature sensor failure. Turn off the appliance and call for service. - Hs: humidity sensor failure. Turn off the appliance and call for service.
Important reminders - Make sure the ductwork is not crushed or restricted. - The installation test is for alerting you to serious problems in the home exhaust system. - The normal operating test may give more accurate information than the installation test, so the results of the two tests may not match exactly.
LG DLEX4000B Owner's Manual, extracted pages 28-30
If the Flow SenseTM LED does not turn on when the cycle ends, the exhaust system is adequate.
Press and hold the Wrinkle Care button for 3 seconds during the cycle. The drum light turns off automatically after 4 minutes.
The warranty is 1 year for parts and labor from the original retail purchase date, and 3 years for the dryer drum for parts only. Customer pays labor or in-home service for the drum after the first year.
They mean there is a temperature sensor failure. Turn off the appliance and call for service.
It means the exhaust system is severely restricted and should be checked immediately, because performance will be poor.
It lights at the beginning of the cycle to remind you to check the lint filter, and it turns off when you press Start/Pause.
Running the dryer with a loose or missing lint filter will damage the dryer and the articles in it.
The front view shows the control panel, lint filters, leveling feet, and reversible door.
Check that it is level front to back and side to side, and that all four leveling feet are in firm contact with the floor.
Possible causes listed are a blown house fuse, a tripped circuit breaker, a power outage, the gas supply or dryer shutoff valves being off, or the Energy Saver option being selected. Make sure the gas shutoffs are fully open, and if using the Normal cycle, deselect Energy Saver.
The manual lists a blown house fuse, a tripped circuit breaker, or a power outage as possible causes. Reset the breaker or replace the fuse. Do not increase fuse capacity. If the problem is a circuit overload, have it corrected by a qualified electrician.